한라IMS

Language

주메뉴

앞서가는 기업, 도전하는 기업, 세계최고의 그날까지 한라IMS는 최선을 다하겠습니다.


Marine Float Type Level Gauge
General
These float level gauges specified in Japanese Industrial Standard
are used for all kinds of tanks in ship.
Feature
FLG-FCG type is a gas tight
Easy maintenance
Easy installation
Easy reading
Exact indication
Classification
Model
Mounting type
Nominal dia.
Application
FLG-FA-100
Inner balance weight

100

Medium tanks

FLG-FA-150
Inner balance weight

150

Large tanks
FLG-FB-100L
FLG-FB-100R
Outer balance weight

100

Large and medium tanks
FLG-FCG-100
Direct acting

100

Removable tanks

FLG-FCG-150
Direct acting

150

Double bottom
(Lubricating oil,
water)tanks
FLG-FCG-200
Direct acting

200

Standard Model and Construction Material
Model
Chamber
Float
Sheave
Spindle
Flange
Wire rope
Sight glass
FLG-FA
SGP

SUS304

SS41

N/A
SS41
SUS304
N/A
FLG-FB
SGP
SUS304
SS41
N/A
SS41
SUS304
N/A
FLG-FCG
SGP
SUS304
N/A
SUS304
SS41
N/A
Hard
Operating Condition
Model
Working condition
Conn.
size
Chamber
size
Max. Measuring
range at
Sp.Gr 0.92
Press.
Temp.
FLG-FA-100
Atm.

80℃

5K100A

100A
-
FLG-FA-150
Atm.
80℃
5K150A
150A
-
FLG-FB-100
Atm.
80℃
5K100A
100A
-
FLG-FCG-100
3㎏/㎠
80℃
5K100A
100A
3000m/m
FLG-FCG-150
3㎏/㎠
80℃
5K150A
150A
6000m/m
FLG-FCG-200
3㎏/㎠
80℃
5K200A
200A
10000m/m